Hobart CL series conveyor dishwashers (CL44e, CL54e, CL64e, CLPS)

Rack conveyor dishwashers with a touch display. Most sensor faults switch the machine off but keep the display on; press Enter to acknowledge once the reading is back in range.

What it is: Conveyor dishwasher

Hobart CL series conveyor dishwashers (CL44e, CL54e, CL64e, CLPS) error codes

CodeMeaningLikely causeWhat to do
001 / 002Booster temperature sensor shorted (reads 115 °C+) / open (reads 0 °C or less)Thermistor, wiring or water in the connectorCheck the thermistor and wiring; dielectric grease on wet connectors. Unplugging it should give 002.
004Rinse temperature not reachedHigh limit tripped, thermistor loose, heaters, contactor, low water or fill valve stuckWork through the booster heating circuit.
006 / 007Wash tank temperature sensor shorted / openThermistor or wiringAs 001 / 002.
015Booster pressure sensor faultSensor or wiringCall service.
016 / 017Wash tank pressure sensor faultSensor or wiringCall service.
018Wash tank level too highDrain blockedClear the drain.
020Tank fill time exceededWater off or drain lever openClose the drain lever; check the water supply.
033 / 140 / 141Booster fill time exceededWater off or drain lever openClose the drain lever; check the water supply.
081 / 082Final rinse temperature sensor faultSensorCall service.
085Wash tank over-temperature trippedHigh limitCall service.
086Booster over-temperature trippedHigh limitCall service.
089Booster contactor errorContactor weldedSwitch off the breaker, do not drain, call service.
138Power rinse over-temperature trippedHigh limitCall service.
160Wash tank temperature not reachedHeaters or contactorCheck tank heat.
184Dirty water alertWash water due for changeDrain and refill.

How to enter service / parameter mode

  1. Switch on and wait for the ready screen.
  2. Press MENU, highlight Login and press ENTER.
  3. Enter the service PIN (from the manual) with the arrow and ENTER buttons.
  4. Use Back to leave the menus.

Other useful key presses

TaskHow
Live sensor readingsService menu → Diagnostics → Analog / Digital inputs and outputs.

Notes

For licensed technicians only. This equipment can involve mains voltage, high-voltage microwave circuits, gas and refrigerant. Isolate power (and gas) before opening panels, follow the manufacturer's manual and your local licensing rules (for example ARC refrigerant handling and electrical or gas licences). Wrong settings can spoil food or damage equipment. Check every value on the unit in front of you before changing it.

Based on: Hobart CL series service and parts manual. Always check the manual for your exact model and software version.