Eversys Cameo range
Compact super-automatic espresso machines. E codes are faults, S codes stop production until you act, W codes are warnings; many are kept in the error history.
What it is: Bean-to-cup espresso machine
Eversys Cameo range error codes
| Code | Meaning | Likely cause | What to do |
|---|---|---|---|
| E-010 | Software does not support this CPU | Version mismatch | Update the software; replace the CPU if it stays. |
| E-011 / E-012 / E-013 / E-014 / E-023 | Hydraulic / milk / brewing / grinder / pump unit not connected | Cable or unit | Check the connection. |
| E-017 | Coffee boiler overheating | Overheat | Machine goes to standby; call service. |
| E-021 | Grinder motor ran non-stop, power cut | Likely a failed triac on the power board | Call service. |
| E-050 | CPU-to-CPU communication error | CAN link failure | Restart; call service if it repeats. |
| E-094 | Standby after boiler overheat | Overheat | Call service. |
| E-095 | Software update running | Wait. | |
| E-097 | Machine type not set | Display and CPU types differ | Set the machine type. |
| E-098 | Software update needed | Display and CPU software differ | Run the update. |
| E-099 | Display lost the CPU over 30 s | Link interrupted | Display restarts itself; otherwise switch off at the main switch for 10 s. |
| E-102 / E-103 | Steam boiler empty / fill timeout | Water tap shut or supply problem | Open the water and press Continue. Hot water and steam are locked until then. |
| E-104 | Steam heating timeout | No pressure after 20 min (start) or 10 min (running) | Check element and controls. |
| E-105 / E-106 / E-107 | Steam boiler connector missing / overheating / pressure sensor fault | Wiring or sensor | Check the sensor and cable. |
| S-002 / S-003 | Left / right bean hopper missing | Not seated | Refit the hopper. |
| S-004 / S-006 | Empty the grounds drawer | Drawer full or cleaning about to start | Empty it. |
| S-007 / S-008 / S-009 | Grounds drawer not inserted | Drawer out or sensor | Refit the drawer. |
| S-010 / S-011 / S-012 | Bean hopper empty or locked | No powder found in the chamber | Refill or unlock the hopper. |
| S-014 | Rinse needed | Boiler may not heat until rinsed | Press the rinse key. |
| S-015 / S-016 | Cleaned without cleaning balls | Dispenser empty, ball stuck, or light barrier dirty | Refill / clear it. Coffee is locked until the next proper clean. |
| S-017 | Cleaning needed | Cleaning due | Hold the rinse key 3 s to start cleaning. |
For licensed technicians only. This equipment can involve mains voltage, high-voltage microwave circuits, gas and refrigerant. Isolate power (and gas) before opening panels, follow the manufacturer's manual and your local licensing rules (for example ARC refrigerant handling and electrical or gas licences). Wrong settings can spoil food or damage equipment. Check every value on the unit in front of you before changing it.
Based on: Eversys Cameo user manual 5700105622. Always check the manual for your exact model and software version.
ServiceModes is not affiliated with Eversys or any other manufacturer. Written in our own words from the manufacturer's documentation.