Faema Emblema
Multi-boiler espresso machine with a display. Faults appear as a check-control number and are kept in an error log with the time and group status.
What it is: Espresso machine
Faema Emblema error codes
| Code | Meaning | Likely cause | What to do |
|---|---|---|---|
| 51 | Pressure sensor reading out of range | Sensor or board fault | Check wiring; replace the sensor or board. |
| 52 | Boiler did not heat within 45 minutes | Safety stat tripped, element open, or triac board | Reset the stat; check element and wiring; replace the triac board. |
| 53 | Turbosteam probe out of range | Probe unplugged or wrong standard data | Re-enter the standard data; check or replace the probe. |
| 58 | Boiler over-pressure (pressure-sensor machines) | Level probe fault and boiler overfilled, or element always on | Check wiring and the level probe. |
| 59 | Boiler refill took over 15 minutes | No water, fill valve, wiring or board | Check the supply and fill valve. |
| 66 | Irregular coffee dose | No water, flow meter, blocked circuit or wiring | Check supply, fittings and the flow meter. |
| 67 | Group wash dispensing irregular | As 66, or group valve | Check the group solenoid valve. |
| 96 | Maintenance due | Service interval reached | Carry out maintenance. |
| 98 | Error log and wash count reset | Log was cleared | Information only. |
| 99 | Default data loaded | Standard data entered | Information only. |
Notes
- The error log shows the time since each fault, the date and hour, and what the groups were doing.
For licensed technicians only. This equipment can involve mains voltage, high-voltage microwave circuits, gas and refrigerant. Isolate power (and gas) before opening panels, follow the manufacturer's manual and your local licensing rules (for example ARC refrigerant handling and electrical or gas licences). Wrong settings can spoil food or damage equipment. Check every value on the unit in front of you before changing it.
Based on: Faema Emblema manual (user and engineer sections), check-control messages. Always check the manual for your exact model and software version.
ServiceModes is not affiliated with Faema or any other manufacturer. Written in our own words from the manufacturer's documentation.