Taylor C713 heat-treatment soft-serve freezer

Twin-barrel heat-treatment freezer. Faults appear on the front display; the Manager’s Menu keeps the last 100 faults and lockouts.

What it is: Soft-serve freezer

Taylor C713 heat-treatment soft-serve freezer error codes

CodeMeaningLikely causeWhat to do
BEATER OVERLOADBeater motor overload trippedStiff product or motorPower off, press the beater reset, power on and restart in Auto.
HPCO COMPRESSORHigh-pressure cut-out openedHot or dirty condenserPower off, wait 5 minutes, power on and restart in Auto.
PRODUCT DOOR OFFDoor not fittedFit the door.
HOPPER THERMISTOR FAILHopper probe failedProbePower off; replace the probe.
BARREL THERMISTOR FAILBarrel probe failedProbePower off; replace the probe.
SHRT / OPEN / OVERProbe reading shorted (under 1 Ω) / open (over 1 MΩ) / above 93 °CProbe or wiringCheck the probe shown.
(L/R) HPR or BRL >41F (5C) AFTER 4 HRMix above 5 °C for over 4 hoursCooling or power lossFollow local food rules; check cooling.
(L/R) HPR or BRL >45F (7C) AFTER 1 HRMix above 7 °C for over 1 hourAs aboveAs above.
(L/R) HPR or BRL >59F (15C)Mix above 15 °CAs aboveAs above.
(L/R) ... AFTER PFTemperature breach after a power failurePower lossAs above.
(L/R) COMP ON TOO LONGCompressor ran past the 11-minute timerLow refrigerant, dirty condenser or low mixCheck refrigeration and mix.
NVRAM FAULT / RESET TO DEFAULTSCorrupt settings, reset to factory defaultsControl memoryRe-enter the settings.

How to enter service / parameter mode

  1. Press the centre of the Cone key for the Manager’s Menu and enter the access code (from the manual) with the arrow and SEL keys.
  2. Fault Description shows current faults; Fault History and Lockout History each hold the last 100.

For licensed technicians only. This equipment can involve mains voltage, high-voltage microwave circuits, gas and refrigerant. Isolate power (and gas) before opening panels, follow the manufacturer's manual and your local licensing rules (for example ARC refrigerant handling and electrical or gas licences). Wrong settings can spoil food or damage equipment. Check every value on the unit in front of you before changing it.

Based on: Taylor C713 operator manual, user interface section. Always check the manual for your exact model and software version.