Alto-Shaam Combitherm CT Express (ES and ESG)

Compact combi oven. When an error shows, press Start to acknowledge it; the flashing mode icons are the modes you can still cook in until it is fixed.

What it is: Combi oven. ES (boiler) and ESG (boilerless) versions; boiler codes only apply to ES.

Alto-Shaam Combitherm CT Express (ES and ESG) error codes

CodeMeaningLikely causeWhat to do
E01Low water in boilerWater supply shut offOpen the supply; check the fill valve.
E02Control too hotCooling fans not runningCheck the fans.
E03 / E04Upper / lower fan motor faultMotor or its drive (VFD) not poweredCheck the drive and motor.
E11Cavity too hotElement contactor stuck onCheck the contactor.
E13Boiler too hotElement not covered by water (scale or fill fault)Descale; check fill.
E15Condenser too hotUntreated water line off or shutOpen the condenser water.
E20Single-point core probe (HACCP only)Probe not fittedFit or check the probe.
E21Cavity probe (N6) openProbe or connectionCheck the probe.
E22Multipoint core probe (B10) faultProbeCook by time only; replace the probe.
E23 / E24 / E25Boiler (B4) / bypass (B5) / condenser (B3) probe openProbe or connection at the relay boardCheck the probe.
E26 / E27Boiler safety probe (N8) open / element too hotProbe fault or scaleCheck the probe; descale.
E34Steam generator drain faultScale or drain pumpDescale; check the pump.
E36Steam temperature highWater offOpen the supply.
E51No water in boiler (fill error)Supply offOpen the supply.
E53 / E54Upper / lower fan motor too hotMotor high limit openCheck the motor and its connection.
E55Vent not openVent motor not poweredCheck the vent motor.
E57No rinse waterSupply off during rinseOpen the supply.
E92 / E94Display board communication errorRibbon cable or boardReseat the cables.

How to enter service / parameter mode

  1. Emergency cooking: press Start to acknowledge the error, pick one of the flashing modes, then press Start. Temperature range may be limited.
  2. Service mode is password protected; the code is in the service manual.

For licensed technicians only. This equipment can involve mains voltage, high-voltage microwave circuits, gas and refrigerant. Isolate power (and gas) before opening panels, follow the manufacturer's manual and your local licensing rules (for example ARC refrigerant handling and electrical or gas licences). Wrong settings can spoil food or damage equipment. Check every value on the unit in front of you before changing it.