Frymaster FilterQuick with FQ3000 controller (FQE30 / FQG30)

Touch controller on FilterQuick gas and electric fryers. It stores the last ten errors in an error log, shown A to J with time and date.

What it is: Fryer controller

Frymaster FilterQuick with FQ3000 controller (FQE30 / FQG30) error codes

CodeMeaningLikely causeWhat to do
E03Temperature probe failureProbe reading out of rangeCheck the probe and its wiring.
E04HI 2 BADHigh-limit reading out of rangeCheck the high-limit sensor.
E05HOT HI 1High limit passed about 210 °C (202 °C on CE units)Let it cool; find why it overheated.
E06Heating failureController, interface board, contactor, gas valve, ignition module or open high limitWork through the heat circuit.
E07MIB software errorInternal fault on the filtration boardPower cycle; update or replace the MIB.
E08ATO board errorMIB lost the auto top-off boardCheck the connection and ATO board.
E09Pump not fillingFilter pad dirty, skipped, or pump problemChange the pad; check the pump.
E10 / E11Drain valve not open / not closedValve position not confirmedCheck the drain valve actuator and switch.
E12 / E13Return valve not open / not closedValve position not confirmedCheck the return valve actuator and switch.
E14AIF board errorMIB cannot see the AIF boardCheck wiring; replace the board.
E15MIB board errorController lost the MIBCheck wiring; replace the MIB.
E16 / E17AIF / ATO probe out of rangeRTD faultCheck the probe.
E20Invalid code locationSD card pulled out during an updateRedo the update.
E21Change filter paper24-hour timer ran outChange the paper.
E22Oil in panOil may be in the filter panEmpty the pan.
E23Clogged drain (gas)Vat did not empty while filteringClear the drain.
E24Oil level sensor failed (gas)Sensor faultCheck the sensor.
E25Recovery faultTook too long to heat back upCheck heat system.
E26Recovery fault, call serviceTwo or more recovery failuresService call.
E28High temperature alarmOil more than about 4 °C (40 °F) over set pointCheck probe and heat control.
E70 / E71Oil quality sensor: oil too hot / too coldOil outside about 149–191 °C when filteringFilter at normal frying temperature.
E72 / E73TPM reading too low / too highFresh oil or wrong oil type set / oil worn outCheck oil type; dispose of spent oil.
E74 / E76OQS internal or communication errorSensor fault or loose connectionCheck connections; power cycle the whole battery.
E75OQS air errorAir getting into the sensorCheck O-rings and the prescreen filter.

How to enter service / parameter mode

  1. From OFF, press the check (✓) key until INFO MODE changes to MAIN, then PRODUCT SETUP.
  2. Scroll to VAT SETUP and press ✓. Enter the vat-setup access code (from the manual).
  3. Scroll to E-LOG and press ✓. NOW shows the current time, then errors A–J. Scroll through them.
  4. Press Exit/Scan three times to return to OFF.

Other useful key presses

TaskHow
Clear error logService menu → Clear E-Log
High-limit testTechnician only: it ruins the oil.

Notes

For licensed technicians only. This equipment can involve mains voltage, high-voltage microwave circuits, gas and refrigerant. Isolate power (and gas) before opening panels, follow the manufacturer's manual and your local licensing rules (for example ARC refrigerant handling and electrical or gas licences). Wrong settings can spoil food or damage equipment. Check every value on the unit in front of you before changing it.

Based on: Frymaster FQ3000 controller manual. Always check the manual for your exact model and software version.

ServiceModes is not affiliated with Frymaster or any other manufacturer. Written in our own words from the manufacturer's documentation.