Schaerer Coffee Club
Compact bean-to-cup machine. Error number and text show when you tap the message field; affected drinks go dark while the rest keep working.
What it is: Super-automatic coffee machine
Key combo: Tap the message field to see the error number. To force a restart, hold the on/off switch.
Schaerer Coffee Club error codes
| Number | Meaning | What to do |
|---|---|---|
| 6 | Brew unit stalled or stiff | Switch off, clean the brew unit. |
| 88 | Boiler over-temperature | Switch off, let it cool, switch on. If it returns, call service. |
| 89 | Boiler heat-up time error | Switch off and on. If it returns, call service. |
| 161 | Flow error: brewing water | Off and on between each step: clean the brew unit, grind coarser, reduce the recipe strength, then call service. |
| 162 | Flow error: during cleaning | Clean the brew unit, then call service. |
| 163 | Flow error: warm rinse | Clean the brew unit, then call service. |
| 186 | Steam boiler level | Steam is blocked for now. Switch off and on. |
| 188 | Steam boiler over-temperature (heating error) | Switch off, unplug, call service. |
| 189 | Steam boiler heat-up time error | Switch off and on. If it returns, call service. |
| 9083 | Milk cooler in frost range | Check the cooler is not set too cold. |
| 9516 | Right grinder blocked | Switch off and unplug. Free the grinder with the multi-tool. Grind one step coarser if it keeps happening. |
| 9517 | Left grinder blocked | As 9516. |
Notes
- First step for any error: switch off, wait a few seconds, switch on and repeat what you were doing.
For licensed technicians only. This equipment can involve mains voltage, high-voltage microwave circuits, gas and refrigerant. Isolate power (and gas) before opening panels, follow the manufacturer's manual and your local licensing rules (for example ARC refrigerant handling and electrical or gas licences). Wrong settings can spoil food or damage equipment. Check every value on the unit in front of you before changing it.
Based on: Schaerer Coffee Club operating instructions. Always check the manual for your exact model and software version.
ServiceModes is not affiliated with Schaerer or any other manufacturer. Written in our own words from the manufacturer's documentation.