Cuber with a one-digit display, RESET, MANUAL DEFROST, CLEAN, FILL and ice thickness + / – buttons. Faults show as a flashing number with matching beeps, and the last five faults are stored.
What it is: Cube ice machine. Machines fitted with the 3rd generation control board.
Key combo: During freeze: hold RESET 3 s until a dash shows, release, then use MANUAL DEFROST to pick a diagnostic number and hold RESET to open it.
Stuart SC130–SC500 (3rd gen board) error codes
| Code | Meaning | Likely cause | How to reset |
|---|---|---|---|
| 3 | Did not fill with water in 3 minutes | Water off, restricted or frozen supply, blocked solenoid strainer or filter, faulty solenoid, float or pump | Retries every hour until water returns. Press RESET to try straight away. |
| 4 | Did not make ice in 40 minutes (low float did not drop) | Partial loss of refrigerant, fan motor, dirty condenser, compressor, hot gas solenoid stuck open, expansion valve | Press RESET, or switch off and on at the power point. |
| 5 | Did not defrost in 7 minutes (curtains did not signal) | Hot gas solenoid, dirty plate, curtain switch, low charge, ice too thin to open the curtain | Press RESET, or switch off and on. |
| 9 | High pressure fault (over 3100 kPa) | Dirty condenser, failed fan, pressure sensor, compressor, very hot site | Fix the cause, then press RESET. |
| 8 (10 beeps, flashes 10 times) | Service due: 3000 hours of ice making | Clean reminder | Repeats hourly until a clean cycle is run. The counter then restarts. |
| 7 | Bin full | Normal | Restarts when both flaps close. |
| 6 | Clean mode | Normal | Press RESET when cleaning is finished. |
How to open the diagnostic display
- Wait until the machine is in normal ice making (compressor and pump running).
- Hold RESET for 3 seconds until a dash shows, then release. 0 flashes.
- Press MANUAL DEFROST to step to the number you want: 0 last five faults, 1 hours since the last clean, 2 clean cycles done, 3 ice harvests, 4 purge setting.
- Hold RESET to confirm. A dash shows; release and the value appears.
- Hold RESET again until a dash shows to go back to ice making.
Settings and limits
| Code | What it does | Range | Default / typical |
|---|---|---|---|
| Purge (diag 4) | Water dumped each cycle, aim for 5–10% of ice weight | 1 (min) to 0 (max) | factory |
| Ice thickness | Ice weight per cycle | 0–9 | factory |
| Fill limit | Time to reach the high float | fixed | 3 min |
| Ice make limit | Time for the low float to drop | fixed | 40 min |
| Defrost limit | Time for the curtains to open | fixed | 7 min |
| High pressure | Trip point | fixed | 3100 kPa |
| Service reminder | Ice making hours between cleans | fixed | 3000 h |
| Board fuse | Main board fuse | — | 3.15 A slow-blow HRC ceramic (no glass fuses) |
How to change a setting
- Water purge: open diagnostic number 4 as above, then press CLEAN to step the purge from 1 (least) to 0 (most). Hold RESET to return. This only works during freeze.
- Ice thickness: press + for thicker (heavier) ice or – for thinner, range 0–9. Set the purge first.
- All buttons except ice thickness need holding 3–5 seconds before they act.
Other useful key presses
| Task | How |
|---|---|
| Warm-up cycle | At power-up the machine defrosts for 2 min then runs the pump 3 min. Press RESET to skip it on first start-up. |
Notes
- The machine makes two attempts at fill, ice making and defrost before it stops on a fault.
For licensed technicians only. This equipment can involve mains voltage, high-voltage microwave circuits, gas and refrigerant. Isolate power (and gas) before opening panels, follow the manufacturer's manual and your local licensing rules (for example ARC refrigerant handling and electrical or gas licences). Wrong settings can spoil food or damage equipment. Check every value on the unit in front of you before changing it.
Based on: Stuart SC130–SC500 manual (3rd generation board). Always check the manual for your exact model and software version.
ServiceModes is not affiliated with Stuart or any other manufacturer. Written in our own words from the manufacturer's documentation.