Ice-O-Matic Elevation Series CIM cubers

Modular cuber controlled by a board with Power and Clean buttons (duplicated on the front push pad), six relay LEDs and switch LEDs for the curtains and floats. Errors show as flash patterns on the Power and Clean LEDs.

What it is: Modular cube ice machine. CIM0335 to CIM1845 (Elevation Series, 2020 manual).

Key combo: From Off (Power LED solid red): hold Power + Clean for 6 s to run Diagnostics. Hold both for 3 s to clear error codes.

Ice-O-Matic Elevation Series CIM cubers error codes

CodeMeaningLikely causeHow to reset
Error 1 – Power LED quick flash redMaximum freeze (1 hour) or maximum harvest (5.5 minutes) exceeded, or bothLow charge, poor condenser airflow, water distribution, curtain switch, hot gas valveFix the cause, then hold Power + Clean 3 s to clear (one blue and one yellow flash confirm).
Error 2 – Power LED slow flash (in Off only)Thermistor (sump water sensor) failureSensor or plugReplace or reconnect the thermistor.
Error 3 – Power LED red + Clean LED yellow quick flashMaximum fill (5 minutes) or maximum purge (2 minutes) exceededWater off, low pressure, inlet valve, float switch, purge valve or drainFix the cause, then hold Power + Clean 3 s to clear.
Power LED slow flash blue (after harvest)Rinse, harvest check, default harvest or 3-minute compressor delayNormalNo action needed. The compressor will not restart for 3 minutes after any stop.
Power LED quick flash blueManual harvest runningPower held 3 s from freezeQuick press Power to cancel.
Power LED double flash redDiagnostics runningStarted from the buttonsQuick press both buttons to step, or hold Power 6 s to stop.

How to start Diagnostics

  1. Make sure the machine is Off (Power LED solid red).
  2. Hold Power and Clean together for 6 seconds. The Power LED double-flashes red.
  3. Quick-press Power and Clean together to step to the next stage of the test (freeze and harvest outputs).
  4. Hold Power for 6 seconds to turn the machine off and leave Diagnostics.

Board limits

CodeWhat it doesRangeDefault / typical
FreezeMinimum / maximum freeze timefixed5 min / 1 h
HarvestMinimum / maximum harvest timefixed20 s / 5.5 min
Water fillMaximum fill timefixed5 min
PurgeMinimum / maximum purgefixed7 s / 2 min
Bin fullCurtain open this long, or bin stat open this long, stops the machinefixed30 s / 90 s
Restart delayCompressor short-cycle protection after any stopfixed3 min
Anti-slushPump stops 20 s when sump water reaches 36 °F (first 3 cycles after restart) or 28 °F (any time)fixed—

How to change a setting (adjustment switch block)

  1. Isolate power before touching the board.
  2. Switch 1: off = 7 s standard purge, on = 5 s extra purge.
  3. Switch 2: on when a bin thermostat kit is fitted (for dispenser installs). Its LED then lights.
  4. Switch 3: off = clean reminder every 6 months, on = every 3 months (hard water).

Other useful key presses

TaskHow
From OffQuick press Power = freeze. Hold Power 3 s = show code revision. Quick press Clean = clean cycle.
Any stateHold Power 6 s = machine off.
During cleanQuick press Clean to move on to purge after at least 5 minutes of wash.

For licensed technicians only. This equipment can involve mains voltage, high-voltage microwave circuits, gas and refrigerant. Isolate power (and gas) before opening panels, follow the manufacturer's manual and your local licensing rules (for example ARC refrigerant handling and electrical or gas licences). Wrong settings can spoil food or damage equipment. Check every value on the unit in front of you before changing it.

Based on: Ice-O-Matic Elevation Series CIM cuber service manual (2020). Always check the manual for your exact model and software version.