Ice-O-Matic GEM / MFI nugget and flake

Auger-type machines with a control board carrying seven indicator lights, infrared ice level sensors in the chute, a reservoir water sensor and high and low pressure cut-outs.

What it is: Nugget / flake ice machine. GEM0450–GEM0956 and MFI0500–MFI1256 (GEM-MFI service manual).

Key combo: No service menu. Read the board lights. Reset an auger overload shutdown by switching power off and on.

Ice-O-Matic GEM / MFI nugget and flake error codes

CodeMeaningLikely causeHow to reset
Power OK light offNo control power, or a pressure cut-out is openNo supply, high or low pressure switch open, failed boardCheck supply and both cut-outs. If both are closed and the light stays off, replace the board.
Water OK light offReservoir water below the sensor tipWater supply, float valve, dirty or open water sensorRestarts by itself once water returns. Test the sensor with an ohmmeter (near zero ohms to the tip).
Service light blinkingAuger motor current too high; restart attempt in 4 minutesScale on the evaporator, worn bearings, gear motorAutomatic retry (twice).
Service light on steadyAuger motor overloaded again after two restartsSame as aboveManual reset: switch power off and back on.
Bin full light onIce blocked the infrared beam for 6 s or moreBin full, or scaled sensorsRestarts after the beam is clear for 10 s. Clean the sensors if needed.
Machine off, all lights normalHigh or low pressure cut-out openDirty condenser, fan, water valve, low chargeBoth cut-outs reset by themselves when pressure recovers.

Service values

CodeWhat it doesRangeDefault / typical
High pressure cut-outAutomatic reset—450 psig
Low pressure cut-outAutomatic reset—15 psig
Start delayAfter switching onfixed10 s
Auger run-onAfter the compressor stopsfixed1 min
Compressor restart delayMinimum off timefixed2 min
Auger amps (typical)GEM0450/MFI0500 and GEM0650/MFI0800 115 V—4.6 A
Auger amps (typical)230/50 models—2.0–2.3 A
Remote low side / dischargeTypical—28–35 / 220–275 psig

Notes

For licensed technicians only. This equipment can involve mains voltage, high-voltage microwave circuits, gas and refrigerant. Isolate power (and gas) before opening panels, follow the manufacturer's manual and your local licensing rules (for example ARC refrigerant handling and electrical or gas licences). Wrong settings can spoil food or damage equipment. Check every value on the unit in front of you before changing it.

Based on: Ice-O-Matic GEM-MFI series service manual. Always check the manual for your exact model and software version.

ServiceModes is not affiliated with Ice-O-Matic or any other manufacturer. Written in our own words from the manufacturer's documentation.