Four-head pressure fryers with a digital timer/temperature control. A fault shows as an E- code with an alarm tone; any button silences it.
What it is: Pressure fryer. PFE-591 is electric, PFG-691 is gas. Codes match except E-20 (gas ignition only) and E-26 (electric only).
Henny Penny Model 591 (electric) and 691 (gas) pressure fryers error codes
| Code | Meaning | Likely cause | What to do |
|---|---|---|---|
| E-4 | Control board too hot | Blocked side louvers or cooling fan not running | Switch off and on. Clear the louvers and check the fan. Replace the control if it stays. |
| E-5 | Oil too hot | Heat circuit stuck on or bad probe | Switch off and on; check the heating circuit and probe. |
| E-6A | Temperature probe open | Probe or wiring broken | Check the probe. |
| E-6B | Temperature probe shorted | Probe or wiring shorted | Check the probe. |
| E-10 | High limit tripped | Overheat | Let it cool, then push up the red reset on the high limit. Replace it if it will not reset. |
| E-15 | Drain switch | Drain open or microswitch fault | Close the drain handle; check the switch. |
| E-20A | Air pressure switch stuck closed (691) | Switch fault | Press the timer button to retry ignition; call service if it stays. |
| E-20B | Combustion fan or air switch stuck open (691) | Fan or switch fault | Retry ignition as above. |
| E-20C | Ignition module failure (691) | Module fault | Retry ignition as above. |
| E-20D | Modules working but no flame (691) | Gas supply, igniter or flame sensing | Retry ignition as above. |
| E-26 | Heat on when it should be off (591) | Shorted element, stuck contactor or failed sensor | Check elements, contactor and sensor. |
| E-41 / E-46 | Programming failure / memory write error | Control memory | Switch off and on, then re-initialise the control. Replace it if it stays. |
| E-47 | Analog converter or 12 V supply fault | I/O board or control board | Switch off and on; replace the I/O or control board. |
| E-48 | Input system error | Control cannot read its buttons | Re-initialise; replace the control. |
| E-70B | Power switch fault | Switch, its wiring or I/O board | Check the switch and wiring. |
| E-92 | 24 V fuse on I/O board open | Short in the 24 V circuit (high limit, drain switch) | Find the short, then replace the fuse. |
How to enter service / parameter mode
- Level 2 programming: hold the PROGRAM button about 5 s and let go when LEVEL 2 appears.
Notes
- Re-initialising the control resets it to factory settings; write down the product settings first.
For licensed technicians only. This equipment can involve mains voltage, high-voltage microwave circuits, gas and refrigerant. Isolate power (and gas) before opening panels, follow the manufacturer's manual and your local licensing rules (for example ARC refrigerant handling and electrical or gas licences). Wrong settings can spoil food or damage equipment. Check every value on the unit in front of you before changing it.
Based on: Henny Penny PFE-591 and PFG-691 technical manuals. Always check the manual for your exact model and software version.
ServiceModes is not affiliated with Henny Penny or any other manufacturer. Written in our own words from the manufacturer's documentation.