Henny Penny Model 591 (electric) and 691 (gas) pressure fryers

Four-head pressure fryers with a digital timer/temperature control. A fault shows as an E- code with an alarm tone; any button silences it.

What it is: Pressure fryer. PFE-591 is electric, PFG-691 is gas. Codes match except E-20 (gas ignition only) and E-26 (electric only).

Henny Penny Model 591 (electric) and 691 (gas) pressure fryers error codes

CodeMeaningLikely causeWhat to do
E-4Control board too hotBlocked side louvers or cooling fan not runningSwitch off and on. Clear the louvers and check the fan. Replace the control if it stays.
E-5Oil too hotHeat circuit stuck on or bad probeSwitch off and on; check the heating circuit and probe.
E-6ATemperature probe openProbe or wiring brokenCheck the probe.
E-6BTemperature probe shortedProbe or wiring shortedCheck the probe.
E-10High limit trippedOverheatLet it cool, then push up the red reset on the high limit. Replace it if it will not reset.
E-15Drain switchDrain open or microswitch faultClose the drain handle; check the switch.
E-20AAir pressure switch stuck closed (691)Switch faultPress the timer button to retry ignition; call service if it stays.
E-20BCombustion fan or air switch stuck open (691)Fan or switch faultRetry ignition as above.
E-20CIgnition module failure (691)Module faultRetry ignition as above.
E-20DModules working but no flame (691)Gas supply, igniter or flame sensingRetry ignition as above.
E-26Heat on when it should be off (591)Shorted element, stuck contactor or failed sensorCheck elements, contactor and sensor.
E-41 / E-46Programming failure / memory write errorControl memorySwitch off and on, then re-initialise the control. Replace it if it stays.
E-47Analog converter or 12 V supply faultI/O board or control boardSwitch off and on; replace the I/O or control board.
E-48Input system errorControl cannot read its buttonsRe-initialise; replace the control.
E-70BPower switch faultSwitch, its wiring or I/O boardCheck the switch and wiring.
E-9224 V fuse on I/O board openShort in the 24 V circuit (high limit, drain switch)Find the short, then replace the fuse.

How to enter service / parameter mode

  1. Level 2 programming: hold the PROGRAM button about 5 s and let go when LEVEL 2 appears.

Notes

For licensed technicians only. This equipment can involve mains voltage, high-voltage microwave circuits, gas and refrigerant. Isolate power (and gas) before opening panels, follow the manufacturer's manual and your local licensing rules (for example ARC refrigerant handling and electrical or gas licences). Wrong settings can spoil food or damage equipment. Check every value on the unit in front of you before changing it.