Nuova Simonelli Prontobar
Bean-to-cup machine whose display spells out the fault. Most alarms block coffee drinks until the cause is fixed.
What it is: Super-automatic espresso machine. Earlier Prontobar with text display. The later Prontobar Touch uses icons for the same faults.
Nuova Simonelli Prontobar error codes
| Display | Meaning | What to check |
|---|---|---|
| DRAWER FULL | Grounds drawer has reached its set count | Empty the drawer and refit it; wait for DRAWER OUT to clear. |
| DRAWER OUT | Grounds drawer not in place | Refit the drawer; check the magnet and magnetic reader and its wiring. |
| FRONT PANEL OPEN | Front panel open, or a bean hopper is out | Close the panel (check the door microswitch); refit the hopper and check its magnetic reader. |
| GROUP ERROR | Brew group took more than 10 s to reach position | Run TEST mode to watch the brew chamber; check the motor encoder plug and board; replace the motor. |
| TOO MUCH COFFEE | Group motor hit its current limit before the encoder count was reached | Upper piston entering the chamber freely; lubricate the group; grind dose too high; motor. |
| ALARM BOILER FILLING | Boiler fill took longer than 90 s and the level probe is still dry | Switch off and on (normal once on first fill); check and clean the fill solenoid and level probe. |
| ALARM COFFEE TEMP | Coffee boiler temperature probe fault | Probe connection; replace probe. |
| ALARM STEAM TEMP | Steam boiler temperature probe fault | Probe connection; replace probe. |
| ALARM GROUP TEMP | Group temperature probe fault | Probe connection; replace probe. |
| PLEASE CLEAN | A cleaning alarm count was reached with the washing block on | Run the washing cycle. |
| REFILL WATER TANK | Water tank empty | Switch off, refill the tank, switch on; check the level sensor position and the tank-present microswitch. |
| Flowmeter error (Touch) | Flowmeter not counting | Check the water supply connection. |
Notes
- This page is based on a scanned alarm list read by eye (no OCR was available). Clint: please check the wording against the PDF.
- On the Prontobar Touch the same faults show as icons, plus lower cylinder and coffee group operating faults: switch off and on, then call service.
For licensed technicians only. This equipment can involve mains voltage, high-voltage microwave circuits, gas and refrigerant. Isolate power (and gas) before opening panels, follow the manufacturer's manual and your local licensing rules (for example ARC refrigerant handling and electrical or gas licences). Wrong settings can spoil food or damage equipment. Check every value on the unit in front of you before changing it.
Based on: Nuova Simonelli Prontobar service manual, alarm section (edition 02/2014, scanned) and Prontobar Touch manual. Always check the manual for your exact model and software version.