Rancilio Classe 20 (ASB, USB, DE)

Multi-boiler espresso machine with touch display. E codes are faults that stop the machine; W codes are warnings about one part, so the rest keeps working.

What it is: Espresso machine

Rancilio Classe 20 (ASB, USB, DE) error codes

CodeMeaningLikely causeWhat to do
E01Boiler did not fill in timeWater supply off or fill valve faultOpen the water; check the fill valve.
E02Boiler pressure not reachedElement, relay or pressure sensorCheck heating and sensor.
E03 / E04Boiler level probe shorted / openProbe or wiringCheck the probe.
E05IDS link missingLost connection to the IDS unitCheck the cable.
E06Softener resin regeneration failedRegeneration did not finishRerun regeneration.
E07Maintenance failureService interval passedService the machine.
E08Washing failureCleaning cycle did not finishRerun cleaning.
E09 / E115 V / 12 V service supply missingPower board or wiringCheck the supplies.
E10Pressure transducer not connectedSensor or cableCheck the connection.
E1212 V power board link missingBoard or wiringCheck the connection.
E13 / E14 / E1524 V to valves / display / triacs missingSupply or wiringCheck the 24 V circuits.
E19Boiler over-pressurePressure control or relay stuckSwitch off; check the pressure control.
E20Boiler safety level triggeredWater level too low or highCheck the level probe and fill.
W01–W03Group 1–3 flow meter not readGrind too fine or flow meter faultCoarsen the grind; check the flow meter.
W08Maintenance dueCounter reachedBook a service.
W20–W49A solenoid valve circuit open or shorted (fill, drain, groups, steam, economiser, profiling)Coil or wiringCheck the valve named on screen.
W70–W75Group 1–3 lighting open or shortedLED or wiringCheck the light.
W92 / W93Cup warmer probe open / shortedProbeCheck the probe.
W96–W101Group 1–3 outer temperature probe open / shortedProbeCheck the probe.
W149–W153Group inner probe over-temperature or set point not reachedHeater, probe or controlCheck the group heater and probe.

Notes

For licensed technicians only. This equipment can involve mains voltage, high-voltage microwave circuits, gas and refrigerant. Isolate power (and gas) before opening panels, follow the manufacturer's manual and your local licensing rules (for example ARC refrigerant handling and electrical or gas licences). Wrong settings can spoil food or damage equipment. Check every value on the unit in front of you before changing it.