Rancilio Classe 9 (USB and S)

Heat-exchange espresso machine with iSteam option. E codes are faults (mostly supply and short-circuit faults); W codes are warnings about one part or a service prompt.

What it is: Espresso machine

Rancilio Classe 9 (USB and S) error codes

CodeMeaningLikely causeWhat to do
E00CPU self-checkControl boardSwitch off and on; replace the board if it stays.
E01Boiler fill timeoutNo waterOpen the supply.
E02Boiler pressure not reached in timeHeating faultCheck element and controls.
E03 / E04Boiler pressure sensor shorted / openSensor or wiringCheck the sensor.
E05IDS link missingCableCheck the connection.
E06 / E07 / E08Softener due / maintenance due / cleaning interrupted (logged)Counters or interrupted cleanAct on the reminder.
E09–E1224 V short on group 1–4Valve coil or wiring on that groupFind the short.
E13Short on general outputs (iSteam, lights)WiringFind the short.
E14Level sensor shortedProbe or wiringCheck the probe.
E15 / E16 / E1812 V short: pressure sensor / flow meter / power boardWiring or partFind the short.
E17External 5 V shortWiringFind the short.
E19Boiler over-pressurePressure controlSwitch off; check pressure control.
W01–W04No signal from group 1–4 flow meterGrind too fine or flow meter faultCheck grind and flow meter.
W05 / W06iSteam temperature sensor shorted / openSensorCheck the sensor.
W07Check dataSettings problemCheck settings.
W08 / W09 / W10Maintenance / softener / coffee cleaning dueCounter reachedAct on the reminder.
W11Check the clockTime lostSet the clock.
W12–W17Group valve 1–4 shorted or openCoil or wiringCheck the valve.
W18 / W19Boiler fill valve shorted / openCoil or wiringCheck the valve.
W22–W25Tea water (4TEA) cold / hot valve shorted or openCoil or wiringCheck the valve.
W26 / W27 / W30 / W31iSteam steam / air valve shorted or openCoil or wiringCheck the valve.
W32 / W33Check message file / USB connectionUSBCheck the stick and file.
W34Purge iSteamFlush neededRun the purge.

Other useful key presses

TaskHow
Factory resetSwitch on while holding button D of the left group for 5 s.

For licensed technicians only. This equipment can involve mains voltage, high-voltage microwave circuits, gas and refrigerant. Isolate power (and gas) before opening panels, follow the manufacturer's manual and your local licensing rules (for example ARC refrigerant handling and electrical or gas licences). Wrong settings can spoil food or damage equipment. Check every value on the unit in front of you before changing it.

Based on: Rancilio Classe 9 user manual (2021-06), list of errors. Always check the manual for your exact model and software version.

ServiceModes is not affiliated with Rancilio or any other manufacturer. Written in our own words from the manufacturer's documentation.