Rational iCombi Pro

Touch-screen combi oven with steam generator, iCareSystem automatic cleaning and, on gas models, burner control. Each fault shows as a Service number with the unit's serial number and software version.

What it is: Combi oven. iCombi Pro (electric and gas). Most numbers match the iCombi Classic.

Rational iCombi Pro error codes

CodeMeaningCan you still cook?What to do
Service 10SC-automatic (steam generator scale control) faultyYesCall a Rational service partner.
Service 11Steam generator water inlet faultyYesCheck the water tap is open, then call service.
Service 12Water quantity measurement wrongYesCall service.
Service 13Steam generator water level not recognizedConvection onlyCall service.
Service 20.1Temperature probe defective (hot air)NoCall service.
Service 20.2 / 20.4Temperature probe defective (moisture)YesCall service.
Service 20.8Temperature probe defective (steam generator)Convection onlyCall service.
Service 25iCareSystem not getting enough water for cleaning—Open the water tap fully, then call service.
Service 26Ball valve cannot find its open positionNoCall service.
Service 27Ball valve cannot find its closed positionNoCall service.
Service 28.1Steam generator temperature limit exceededNoCall service.
Service 28.2Cooking cabinet temperature limit exceededNoCall service.
Service 28.4Cabinet temperature limit exceeded (steam side)Convection onlyCall service.
Service 30Humidity measurement wrongYesCall service.
Service 32.1–32.3 / 33.1–33.3Gas burner faultyNoClose the gas shut-off valve and call service.
Service 34.1 / 34.2 / 34.4Internal data communication faultyNoCall service.
Service 34.8Automatic clean not workingYesCall service.
Service 34.32Internal data communication faulty (gas)YesCall service.
Service 36 / 37Differential pressure sensor defectiveYesCall service.
Service 40Not enough care liquid for the iCareSystemYesCheck the care tabs/liquid, then call service.
Service 42.x / 46.1 / 49.xWater supply faultyYes (42.1: convection only; 42.3: no steam injection)Check the water supply, then call service.
Service 43.xInternal water supply not closingConvection onlyCall service.
Service 47.1 / 47.2Waste water pump defectiveYesCall service.
Service 48.1 / 48.2Circulating pump defectiveYesCall service.
Service 60Ignition box did not initialize—Switch off and on again. Call service if it stays.
Service 110SC pump error during automatic cleanNoCall service.
Service 120Water level detection error during automatic cleanNoCall service.

Other useful key presses

TaskHow
Hide a messageSwipe the error away while you wait. It shrinks to a red symbol at the side; tap it to bring it back.
Service dataService data can be viewed under Settings › Service.

Notes

For licensed technicians only. This equipment can involve mains voltage, high-voltage microwave circuits, gas and refrigerant. Isolate power (and gas) before opening panels, follow the manufacturer's manual and your local licensing rules (for example ARC refrigerant handling and electrical or gas licences). Wrong settings can spoil food or damage equipment. Check every value on the unit in front of you before changing it.

Based on: Rational iCombi Pro operating instructions (6-2/3, English UK), section 19.5. Always check the manual for your exact model and software version.