Rational iCombi Pro service level, calibration and gas errors

What the service level holds, the codes the self-test and calibration can give, the common gas burner errors, and the board LED codes.

What it is: Combi oven. Technician-level details for the iCombi Pro. For the Service numbers shown to users, see the iCombi Pro page.

Rational iCombi Pro service level, calibration and gas errors error codes

CodeMeaningLikely causeWhat to do
(1|2) / (1|4) / (1|8)Calibration: B1 / B2 / B4 sensor too hotOven not cool enough to start (all must be under 40 °C)Let it cool. Codes can combine.
(2|1) / (2|2)Calibration: differential pressure too low / too highPressure sensor P1 faulty or unpluggedCheck P1.
(4|1), (10|1), (15|1)Calibration value too smallHose changed, water in the hose, or P1 faultyCheck the hose and P1.
(4|2), (10|2), (15|2)Calibration value too largeAs aboveAs above.
TimeoutA calibration step timed oute.g. door open, heater or SSR faultFix and rerun.
Step 20Calibration finished successfully
19 / 29 / 39Burner (upper hot air / steam / lower hot air) went out 5 times while runningGas supply or flame sensingCheck gas and ignition.
22 / 32 / 42Ignition failed 5 timesGas, igniter or electrodeCheck ignition.
20 / 30 / 40Burner fan speed too far from set pointFan or speed signalCheck the blower.
110Scale-control pump fault while cleaner is in the steam generatorPumpCheck the pump.
120Level electrode no signal while cleaner is in the steam generatorElectrodeCheck the electrode.
121Running without waterWater offFill the water.
I/O supply LED code 1–6Supply voltage / STM32 link / capacitive button / high-limit wiring / low-limit wiring / mains frequency not recognisedBoard or wiringCheck the item named.

How to enter service / parameter mode

  1. The service level is reached from Settings › Service; it asks for the technician password (from Rational, not shown here).
  2. Inside: basic settings and calibration, notification centre, and for each module (steam, convection, moisture, iCareSystem) diagnosis, module test, function test and service error history.

Other useful key presses

TaskHow
Self-testNeeded on new installs. Put a closed GN container 20 mm deep, open side down, in front of each fan wheel. Gas units need a flue gas check afterwards.
When to recalibrateAfter replacing P1, the B4 sensor, a fan wheel, or the board and SD card together; after fitting hoods, new racks or a Combi-Duo; or if cooking is uneven.
Board replacementMove the micro SD card to the new board; the unit restores its software backup, then update to the latest software.
eSTB resetAfter fixing the cause, hold the eSTB reset button 3 s.

For licensed technicians only. This equipment can involve mains voltage, high-voltage microwave circuits, gas and refrigerant. Isolate power (and gas) before opening panels, follow the manufacturer's manual and your local licensing rules (for example ARC refrigerant handling and electrical or gas licences). Wrong settings can spoil food or damage equipment. Check every value on the unit in front of you before changing it.

Based on: Rational iCombi Pro service reference sheet. Always check the manual for your exact model and software version.