Vulcan VC4G / VC6G gas convection ovens (computer control)

Full-size gas convection ovens. On the computer control a fault code alternates with the cavity temperature on the display; normal running resumes once the cause is gone.

What it is: Convection oven. Error codes apply to the VC4GC and VC6GC computer control. Manual-control models have no codes.

Vulcan VC4G / VC6G gas convection ovens (computer control) error codes

CodeMeaningLikely causeWhat to do
Er01 / Er02ROM / RAM check failedInternal control faultSwitch off and on.
Er03Ambient sensor errorControl area below 0 °CCheck the temperature at the control.
Er04Configuration errorControl faultSwitch off and on.
Er05EEPROM errorPower lost while savingSwitch off and on.
Er06Zone 1 reading too lowWrong sensor type set, or temperature outside rangeCheck setup parameter InP1 matches the sensor; check for a reversed or open probe.
Er07Zone 1 reading too highOpen sensorAs above.
Er10Stack overflowControl faultSwitch off and on; check the sensor wiring.
Er11Open sensorProbe or wiring openCheck InP1 and the probe.
Er12Shorted sensorProbe shorted or wrong typeCheck InP1 and the probe.

Notes

For licensed technicians only. This equipment can involve mains voltage, high-voltage microwave circuits, gas and refrigerant. Isolate power (and gas) before opening panels, follow the manufacturer's manual and your local licensing rules (for example ARC refrigerant handling and electrical or gas licences). Wrong settings can spoil food or damage equipment. Check every value on the unit in front of you before changing it.

Based on: Vulcan VC4G/VC6G service manual F24682 Rev J. Always check the manual for your exact model and software version.

ServiceModes is not affiliated with Vulcan or any other manufacturer. Written in our own words from the manufacturer's documentation.

Back to top ↑