WMF WMF 5000 S+

Fully automatic coffee machine. Messages carry a four-digit number: 1a–1d are operating events, 2 is a fault, 3a/3b is maintenance.

What it is: Bean-to-cup coffee machine

WMF WMF 5000 S+ error codes

CodeMeaningLikely causeWhat to do
9013Brewer motor faultEncoder or its cableCheck the encoder and cable.
9017Brewer could not homeGrounds or a stiff brewer in the chamberSwitch off and on; clean the brewer.
9053 / 9055Cleaning due / forced cleaningCleaning interval passed or a clean was interruptedRun cleaning. With 9055 coffee is blocked until you do.
9063 / 9064Grinder running emptyBeans out or idle-current level wrongRefill beans; redo the idle-current calibration.
9068 / 9069Grounds container missing / fullRemoved, full, or switch faultRefit or empty it (leave it out long enough to reset the count).
9074Operating panel openPanel raised or switch faultClose it; check the switch.
9076 / 9087 / 9667 / 9668Water pressure missing or too lowSupply shut or pressure droppingOpen the supply fully; check site pressure and the pressure switch.
9077Leak water detectede.g. a valve leaking from scaleFind and fix the leak.
9078Water filter used upSet filter capacity reachedChange the filter.
9091 / 9092Brewer service / descaling dueCounter reachedChange the brewer / descale.
9123 / 9532Brewer did not reach positionWeak drive or blockageSwitch off and on; check the brewer and motor.
9216Brewing time limitGrind too fine or too much coffeeCoarsen the grind.
9335 / 9336Steam boiler over-temperature / sensor breakOver 200 °C or broken sensorCheck or replace the sensor.
9400Configuration faultyBad configuration fileLoad a backup from USB.
9406Internal communication timeoutCAN or serial linkCheck the cables.
9429Brewer motor timeoutBrewer dirty or jammedClean the brewer; check motor and drive.
9456 / 9458 / 9459Overcurrent on brewer / valves / motorsShorted partFind and replace the part.
9477 / 9478 / 9479Power faultSupply out of range or 24/30 V part drawing too muchCheck the supply and low-voltage parts.
9480Minimum flow while brewingWrong settings or flow problemConfirm, then reset the settings.
9484Boiler fill timeout on first heatWater tap shutOpen the supply.
9490Brewer too stiffBrewer dirty or quality levelClean or adjust.
9512Brew temperature sensor breakSensor faultReplace the sensor.
9516 / 9517Grinder 1 / 2 blockedForeign body or grind too fineClean the grinder; adjust the grind.
9575 / 9576Grinder idle-current check failedBean hoppers not lockedLock the hoppers and retry.
9634 / 9635Database errorFront panel data faultRestart; replace the front panel if it stays.
9880Clock not setTime lostSet the time.
9883 / 9890Power stage firmware mismatchFirmware out of dateUpdate the power stage.

Notes

For licensed technicians only. This equipment can involve mains voltage, high-voltage microwave circuits, gas and refrigerant. Isolate power (and gas) before opening panels, follow the manufacturer's manual and your local licensing rules (for example ARC refrigerant handling and electrical or gas licences). Wrong settings can spoil food or damage equipment. Check every value on the unit in front of you before changing it.

Based on: WMF 5000 S+ event and failure list (2022). Always check the manual for your exact model and software version.

ServiceModes is not affiliated with WMF or any other manufacturer. Written in our own words from the manufacturer's documentation.

More WMF pages

Back to top ↑