Scotsman AC / EC 47–177 (R290)

Compact spray cubers with an electronic board, push button, LED panel and DIP switch. AC models make gourmet cubes, EC models standard cubes.

What it is: Self-contained cube ice maker. Covers AC and EC 47, 57, 87, 107, 127, 147 and 177 on R290.

Key combo: Push button 2–5 s during water fill for Cleaning Mode. More than 5 s skips fill, forces harvest, or ends harvest. Hold more than 20 s to reset the cleaning reminder.

Scotsman AC / EC 47–177 (R290) error codes

CodeMeaningLikely causeHow to reset
Red alarm LED on steadyCondenser too hot (over 70 °C air, 60 °C water cooled)Blocked condenser filter, fan motor fault, short of condenser water, room over 40 °CFix the cause, switch off, wait a few seconds and switch on. It restarts with a 5-minute fill.
Red alarm LED blinkingEvaporator above 0 °C 15 minutes after freeze startedLeaking hot gas or inlet valve, short of refrigerant, compressor cyclingRepair the cause.
Freezing + red LED on steadyCondenser sensor out of orderSensor or wiringReplace the sensor.
Freezing + red LED blinkingEvaporator sensor out of orderSensor or wiringReplace the sensor.
Bin full LED onUnit off on full binNormal, or a faulty level controlClean or replace the level control if it stays on.
Bin full LED blinking slowInfrared beam brokenIce in the beamClears when the beam is clear.
Bin full LED blinking fastBeam restored after a full-bin stopNormal—
LEDs blinking alternatelyInfrared sensor out of orderSensor faultReplace the level control.
Freezing LED blinking60-minute start delay (jumper J3 out)SettingPress the button during the delay to skip it.

How to use the push button

  1. During the water fill phase, press the push button for 2 to 5 seconds to start Cleaning Mode.
  2. Press for more than 5 seconds during fill to go straight to freeze.
  3. Press for more than 5 seconds during freeze to go to harvest, or during harvest to go back to freeze.

Key settings

CodeWhat it doesRangeDefault / typical
DIP 1–4Timed end of freezeper chartper model
DIP 5–6Harvest program A/B/C/DA–Dper model
Harvest lengthSet by evaporator time from 0 °C to −15 °C90–180 s—
Water fillFill at start-upfixed5 min
Condenser cut-outHigh condensing temperature stop70 °C air / 60 °C water—

How to change a setting (DIP switch)

  1. Isolate power first.
  2. Set DIP keys 1–4 for the timed part of freeze, 5–6 for the harvest program (A–D) and the remaining keys as per the model chart in the manual.
  3. Restore power.

Notes

For licensed technicians only. This equipment can involve mains voltage, high-voltage microwave circuits, gas and refrigerant. Isolate power (and gas) before opening panels, follow the manufacturer's manual and your local licensing rules (for example ARC refrigerant handling and electrical or gas licences). Wrong settings can spoil food or damage equipment. Check every value on the unit in front of you before changing it.

Based on: Scotsman AC/EC 47–177 R290 service manual. Always check the manual for your exact model and software version.

ServiceModes is not affiliated with Scotsman or any other manufacturer. Written in our own words from the manufacturer's documentation.

More Scotsman pages

Back to top ↑