Scotsman EC106 / EC126 / EC176 / EC206 / EC226

Spray-type cuber. The PC board reads evaporator, condenser and infrared bin sensors; LEDs on the board and a red alarm light on the front report faults.

What it is: Self-contained cube ice maker. European-built Scotsman (Frimont) cubers with a 4-LED PC board, red alarm/reset button and 10-way DIP switch.

Key combo: Press the board push button 2–5 s during water fill for Cleaning Mode, or more than 5 s to skip fill, force harvest or force freeze. Hold the red reset button 5 s to reset a high-temperature trip.

Scotsman EC106 / EC126 / EC176 / EC206 / EC226 error codes

CodeMeaningLikely causeHow to reset
Red alarm LED on steadyCondensing temperature too high (over 70 °C air, 60 °C water cooled)Dirty condenser or air filter, fan motor fault, no condenser water, hot roomFix the cause, then hold the red reset button 5 s until the light goes out.
Red alarm LED blinkingEvaporator still above 0 °C 15 minutes into freezeLeaking hot gas or water inlet valve, short of refrigerant, compressor cyclingFind and fix the cause before restarting.
Freezing LED + red LED on (front light blinks twice and repeats)Condenser sensor out of orderFailed sensor or wiringReplace the sensor, then hold reset 5 s.
Freezing LED + red LED blinkingEvaporator sensor out of orderFailed sensor or wiringReplace the sensor.
Bin full yellow LED onStopped on full binNormal, or a faulty ice level controlRestarts 6 s after the beam clears. Clean or replace the level control if it stays on.
Bin full LED blinking slowInfrared beam brokenIce in the beam, dirty sensorClears when the beam is restored.
Bin full LED blinking fastBeam restored after a bin-full stopNormal—
Bin full LED blinking alternatelyInfrared sensor out of orderSensor faultClean or replace the level control.
Freezing LED blinking60-minute start-up delay active (jumper J3 out)Normal settingPress the push button during the delay to skip it.
Front red light steady (machine on)Condenser air filter needs cleaningReminderClean the filter.
Front red light slow blink (machine on)Water system due for cleaningReminder (6 or 12 months)After cleaning, hold the red reset button for more than 20 s until it blinks.

How to use the board push button

  1. To clean: during the water fill phase, press the board push button for more than 2 but less than 5 seconds.
  2. To skip the water fill: press it for more than 5 seconds during fill.
  3. To force a harvest: press it for more than 5 seconds during freeze.
  4. To end a harvest early: press it for more than 5 seconds during harvest.

DIP switch settings

CodeWhat it doesRangeDefault / typical
DIP 1–4Length of the timed end of freeze16 combinations1–25 min (per model chart)
DIP 5–6Harvest program: ON-ON A, ON-OFF B, OFF-OFF C, OFF-ON DA–Dper model
DIP 7–8Extra harvest time: ON-ON 0, OFF-ON 30 s, ON-OFF 60 s, OFF-OFF 90 s0–90 sper model
DIP 9Pump run at start of harvestoff 15 s / on 30 sper model
DIP 10Condenser cut-out temperatureon 70 °C / off 60 °Cair on, water off
Jumper J3Start-up delayin 3 min / out 60 min—
Harvest lengthSet by how long the evaporator takes to go from 0 °C to −15 °C90–180 s—

How to change a setting (DIP switch)

  1. Switch the machine off and isolate power before touching the board.
  2. DIP keys 1–4 set the timed (second) part of freeze, from 1 to 25 minutes.
  3. Keys 5 and 6 pick the harvest program (A, B, C or D) for cube size.
  4. Keys 7 and 8 add 0, 30, 60 or 90 s of extra harvest time.
  5. Key 9 runs the water pump for the first 15 s (off) or 30 s (on) of harvest.
  6. Key 10 sets the condenser cut-out to 70 °C (on, air cooled) or 60 °C (off, water cooled).
  7. Restore power. The board reads the switches at start-up.

Notes

For licensed technicians only. This equipment can involve mains voltage, high-voltage microwave circuits, gas and refrigerant. Isolate power (and gas) before opening panels, follow the manufacturer's manual and your local licensing rules (for example ARC refrigerant handling and electrical or gas licences). Wrong settings can spoil food or damage equipment. Check every value on the unit in front of you before changing it.

Based on: Scotsman EC106–EC226 service manual (rev. 2015-11). Always check the manual for your exact model and software version.

ServiceModes is not affiliated with Scotsman or any other manufacturer. Written in our own words from the manufacturer's documentation.