Elitech E-1000
"Super-easy" controller with separate cool-on and heat-on temperatures, off-cycle defrost and a light relay, set from labelled keys.
What it is: Heat/cool controller with lighting
Key combo: Hold the lock key 5 s for the F1–F7 system menu.
Elitech E-1000 error codes
| Code | Meaning | Likely cause | How to reset |
|---|---|---|---|
| Err | Settings did not save | Memory write error while saving or resetting | Returns to normal after a few seconds. Power-cycle and try again. |
| rES / YES | Factory reset prompt / done | Lock key held 10 s while locked | Press the confirm key within 3 s to reset. |
How to enter service / parameter mode
- The keypad locks after 30 s idle. Press the lock key 1 s to unlock (short beep).
- Cool-on or heat-on temperature: press its key, adjust with up/down; it saves when you press the lock key or after 30 s.
- System menu: hold the lock key more than 5 s until F1 shows.
Parameter list
| Code | What it does | Range | Default / typical |
|---|---|---|---|
| Heat on | Heating switches on at or below this | −40 °C to cool-on − both hysteresis values | −10.0 °C |
| Cool on | Cooling switches on above this | Heat-on + both hysteresis values to 85 °C | 10.0 °C |
| F1 | Defrost time | 1 to 120 min | 30 |
| F2 | Defrost interval | 0 to 120 h | 6 |
| F3 | Interval counts | 0 controller on time, 1 compressor run time | 1 |
| F4 | Cooling hysteresis | 0.5 to 20 °C | 2 |
| F5 | Heating hysteresis | 0.5 to 20 °C | 2 |
| F6 | Probe offset | −10 to 10 °C | 0 |
| F7 | Compressor restart delay | 0 to 20 min | 3 |
How to change and save a setting
- Step with up/down, press the lock key to show the value.
- Adjust with up/down and press the lock key to store.
- Hold the lock key 3 s, or wait 30 s, to save and exit.
Other useful key presses
| Task | How |
|---|---|
| Lights on/off | Press the light key |
Notes
- Cooling stops at cool-on minus F4; heating stops at heat-on plus F5.
- Defrost is off-cycle: the compressor simply stops for F1 minutes.
- Cool-on, heat-on and the two hysteresis values limit each other so the bands cannot overlap.
For licensed technicians only. This equipment can involve mains voltage, high-voltage microwave circuits, gas and refrigerant. Isolate power (and gas) before opening panels, follow the manufacturer's manual and your local licensing rules (for example ARC refrigerant handling and electrical or gas licences). Wrong settings can spoil food or damage equipment. Check every value on the unit in front of you before changing it.
Based on: Elitech E-1000 temperature controller instruction. Always check the manual for your exact model and software version.
ServiceModes is not affiliated with Elitech or any other manufacturer. Written in our own words from the manufacturer's documentation.
More Elitech pages
- Elitech ECS-180, ECS-180neo and ECS-2280neoRefrigeration controller
- Elitech STC-1000, STC-1000HX and STC-1000XHeat/cool thermostat
- Elitech STC-8000HX and STC-8080HXCooling thermostat
- Elitech STC-200+Cool/heat/alarm thermostat
- Elitech ECS-02CXRefrigeration controller
- Elitech ECS-06CXRefrigeration controller
- Elitech ECS-16Beverage cooler controller
- Elitech ECS-961neoRefrigeration controller
- Elitech ETC-902Heat/cool controller
- Elitech EK-3010 and EK-3010LCool room / heating controller
- Elitech EK-3030ECool room controller
- Elitech ECS-974neo and ETC-974ARefrigeration controller
- Elitech MTC-6040Temperature and humidity controller
- Elitech EK-3030Refrigeration temperature controller
- Elitech EK-3020 / EK-3021Refrigeration temperature controller
- Elitech ECB-1000PLUS / ECB-1000PLUS CloudCold room control board
- Elitech ECB-LS230 (ECB-LS2xx split control box)Cold room control box
- Elitech LS-200 split control boxCold room control box
- Elitech STC-1000Pro TH / STC-1000WiFi THPlug-in temperature and humidity controller