Elitech ECS-961neo
One-probe, one-relay (17 A) cabinet controller with off-cycle defrost timing, cooling or heating mode, and an access-code administrator menu.
What it is: Refrigeration controller
Key combo: Tap Set for the set point. Hold Set 5 s for PA1 (administrator access code).
Elitech ECS-961neo error codes
| Code | Meaning | Likely cause | How to reset |
|---|---|---|---|
| E1 | Probe fault | Room probe open or shorted | Compressor follows Ont/OFt: Ont 0 = off, OFt 0 = on, both above 0 = cycling. Clears once the probe reads. |
| Er | Copy card failed | Card not seated or faulty | Reseat and repeat. |
| EP | Copy card data does not match | Card from another model | Use the right card or upload to it first. |
| LOC | Set point locked | LOC = y | Change LOC to n in the administrator menu. |
| rSt | User values restored | Up + down held 10 s | Information only. |
How to enter service / parameter mode
- Hold Set for 5 seconds: PA1 shows. If PA1 is set to 0 the administrator list opens directly.
- Otherwise press Set (00 shows), enter the administrator access code with up/down and press Set. If the code is right the list opens at diF; if wrong, the controller drops back to normal.
Parameter list
| Code | What it does | Range | Default / typical |
|---|---|---|---|
| SEt | Set point | LSE to HSE | 4.0 °C |
| diF | Differential | 0.1 to 30.0 °C | 2.0 |
| HSE | Highest set point | SEt to 99 °C | 90.0 |
| LSE | Lowest set point | −50 °C to SEt | −50.0 |
| Ont | On time with probe fault | 0 to 250 min | 0 |
| OFt | Off time with probe fault | 0 to 250 min | 1 |
| dOF | Compressor restart delay | 0 to 250 min | 0 |
| OdO | Output delay at power-up | 0 to 250 min | 0 |
| dit | Defrost interval | 1 to 250 h | 6 |
| dCt | Interval counts | 0 compressor run time, 1 clock time, 2 compressor off time | 1 |
| dOH | Delay before first defrost | 1 to 59 min | 1 |
| dEt | Defrost time (0 = no defrost) | 0 to 250 min | 30 |
| dPO | Defrost at power-up | n / y | n |
| LOC | Lock set point | n / y | n |
| PA1 | Administrator access code (set your own; 0 = no code) | 0 to 250 | see manual |
| ndt | Show decimal point | n / y | y |
| CA1 | Probe offset | −12.0 to 12.0 °C | 0 |
| ddL | Display in defrost | 0 live, 1 frozen until back at set point, 2 dEF until back at set point | 1 |
| HC | Mode | 0 cooling, 1 heating | 0 |
How to change and save a setting
- Pick a code with up or down and press Set.
- Adjust with up or down, then press Set to go back to the list.
- Press the defrost key, or wait 30 s, to save and exit.
Other useful key presses
| Task | How |
|---|---|
| Manual defrost on/off | Hold the defrost key 3 s |
| Restore user values | Hold up + down 10 s until rSt |
| Copy card upload / download | Card in, hold up (uP) or down (do), remove after 5 s |
Notes
- The manual's display-code table swaps the meanings of uP and do. The key steps (up = upload to card, down = download to controller) are the reliable part.
- Defrost is off-cycle: the compressor simply stops for dEt minutes.
For licensed technicians only. This equipment can involve mains voltage, high-voltage microwave circuits, gas and refrigerant. Isolate power (and gas) before opening panels, follow the manufacturer's manual and your local licensing rules (for example ARC refrigerant handling and electrical or gas licences). Wrong settings can spoil food or damage equipment. Check every value on the unit in front of you before changing it.
Based on: Elitech ECS-961neo temperature controller manual. Always check the manual for your exact model and software version.
ServiceModes is not affiliated with Elitech or any other manufacturer. Written in our own words from the manufacturer's documentation.
More Elitech pages
- Elitech ECS-180, ECS-180neo and ECS-2280neoRefrigeration controller
- Elitech STC-1000, STC-1000HX and STC-1000XHeat/cool thermostat
- Elitech STC-8000HX and STC-8080HXCooling thermostat
- Elitech STC-200+Cool/heat/alarm thermostat
- Elitech ECS-02CXRefrigeration controller
- Elitech ECS-06CXRefrigeration controller
- Elitech ECS-16Beverage cooler controller
- Elitech ETC-902Heat/cool controller
- Elitech EK-3010 and EK-3010LCool room / heating controller
- Elitech EK-3030ECool room controller
- Elitech ECS-974neo and ETC-974ARefrigeration controller
- Elitech E-1000Heat/cool controller with lighting
- Elitech MTC-6040Temperature and humidity controller
- Elitech EK-3030Refrigeration temperature controller
- Elitech EK-3020 / EK-3021Refrigeration temperature controller
- Elitech ECB-1000PLUS / ECB-1000PLUS CloudCold room control board
- Elitech ECB-LS230 (ECB-LS2xx split control box)Cold room control box
- Elitech LS-200 split control boxCold room control box
- Elitech STC-1000Pro TH / STC-1000WiFi THPlug-in temperature and humidity controller